GEYSER TIMER

R799.00

Category: Tag:

Features:
– 7 Day Digital Timer (Relay contacts)
– Rated Voltage: 220 – 240V AC (50 – 60 Hz)
– Relay contacts for various voltage ranges
– Max 20A (3500 Watts) – resistive load (geysers, underfloor heating, lights)
– Max 10A – inductive load (pool pump, aircon)
– Day/Weekly 16 programmable settings
– Din rail mounting
– 3 Year backup battery
– LCD displays real time hour/minute – on/auto/off

How to Set a Geyser Timer? 

To set the time on the clock

  • Hold the time button down( C ).(bottom left corner button)
  • Press the W (week button) until it is the present day of the week (you will see the week display along the top of the screen)
  • Keep holding the time button and press the H (hour button) until the hours come to the present time.
  • Do the same with the M (minute button)
  • The time is now set !!!!

To set the timer to switch geyser on and off

You can set the timer 7 times a day 7 days a week. When pushing the timer button (bottom middle button indicated by a circle with a line through it) for the first time you will see a number 1 come up in the bottom left corner of the screen. This will be TIMER 1 on, if you press it again it will be timer 1 off, press again and it will come to timer 2 on and so on etc.

  • Press timer button once so timer (1 on) is indicated, and then keep push the W button until all the days (Monday to Sunday) appears on the top of the screen.
  • Press H (hour button) to set to the desired hour for your geyser to come on
  • Press M (minute button) for the desired minutes to come on
  • Press timer button again and timer (2 on) will appear in the left bottom corner
  • Repeat numbers (1,2 and 3)
  • If you want your geyser timer to go on and off a third time per day, repeat numbers 1,2 and 3

Once you have finished setting your timer push the (C) clock button then push your manual button (bottom right button) until you timer goes onto the auto position which is displayed on the bottom middle of the screen

Your manual button has 4 settings:

ON setting is when your geyser will stay on all the time

Off setting is when your geyser will stay off all the time

AUTO ON is when the timer is engaged with your desired times of being on

AUTO OFF is when the timer is engaged with your desired times of being off

If for any reason you find you have cold water and need hot water, keep pushing your manual button until the red light comes on and you will have hot water in 45 minutes. 

Afterwards switch to Auto and check your timer settings by pushing your timer button (bottom middle)